AWG Wire Gauge Chart

Diameter, area in mm² and circular mils, and copper resistance for every AWG size from 4/0 to 40, with a converter from diameter or mm² to the nearest gauge.

mm

Measure the metal with a caliper, not the insulation. Solid wire only: stranded wire measures a little larger.

mm²
Wire gauge —
AWG wire gauge chart

How to use the AWG chart

Pick a gauge to see its diameter, area and resistance. To identify an unknown wire, choose find the gauge from a diameter, strip a little insulation and measure the bare metal with a caliper. To convert a metric (IEC) size, choose find the gauge from an area in mm². The full AWG wire gauge chart below the result highlights the gauge you picked.

How the AWG system works

American Wire Gauge numbers come from the number of drawing steps in old wire mills, which is why a bigger number means a thinner wire. The sizes follow a fixed formula:

d = 0.005 in × 92(36 − n) ÷ 39

Here n is the gauge number; 1/0 is n = 0, 2/0 is n = −1, 3/0 is −2 and 4/0 is −3. Three useful rules follow from it:

  • Every 3 gauges the area, and the weight, roughly doubles or halves, and the resistance does the opposite.
  • Every 6 gauges the diameter doubles or halves.
  • Every 10 gauges the area changes about ten times. 10 AWG copper is close to 1 Ω per 1,000 ft.

Read more in AWG explained.

Common building-wire sizes

AWGDiameter (in)Diameter (mm)Area (mm²)Nearest metric size
140.06411.6282.082.5 mm²
120.08082.0533.314 mm²
100.10192.5885.266 mm²
80.12853.2648.3710 mm²
60.16204.11513.316 mm²
40.20435.18921.225 mm²
20.25766.54433.635 mm²
1/00.32498.25253.570 mm²
4/00.460011.68107120 mm²

Solid-wire diameters. Stranded wire of the same gauge has the same metal area but measures a few percent larger across. The “nearest metric size” is the next IEC size up, the safe direction when you swap a metric cable for an AWG one.

kcmil sizes

Above 4/0, wire is sized in thousands of circular mils (kcmil, once written MCM). A circular mil is the area of a circle one thousandth of an inch across, so a wire’s area in circular mils is simply its diameter in mils squared. 4/0 is 211.6 kcmil, so the next size up is 250 kcmil.

Frequently asked questions

What is the diameter of 12 gauge wire?

0.0808 in, or 2.05 mm, for solid wire. Its area is 3.31 mm² or 6,530 circular mils.

Is 2.5 mm² the same as 14 AWG?

Not quite. 2.5 mm² sits between 14 AWG (2.08 mm²) and 12 AWG (3.31 mm²), closest to 13 AWG. Building codes do not treat them as interchangeable.